Why fan impeller blades cracked: resonance at 350 Hz

A client recently sent us several centrifugal fan impellers. They all had the same problem: fatigue cracks appearing where the blades weld to the backplate.

The client was confused. There was no overload, and the material quality was perfect. So we started an in-depth investigation.

Here is what my colleague found. He measured the natural frequency of the blades and found it to be exactly 350 Hz.

Then we looked at the operating data:

Fan rotation speed: 50 Hz

Number of blades: 7

If you calculate the blade passing frequency (the rate at which blades pass the cutoff), the math reveals the problem:

50 Hz (speed) x 7 (blades) = 350 Hz

The verdict: resonance. We hit a perfect 1:1 resonance. Every time a blade passes the cutoff, the aerodynamic pulse hits it at the exact moment it is naturally vibrating. This amplifies the stress in the metal until it cracks.

The failure wasn't caused by "heavy loads". It was caused by physics.