Exhaust fan impeller balancing in an auto body shop

Two-plane dynamic balancing of an exhaust fan impeller in an auto body shop.

Measurement results:

Vibration before balancing: 15 and 42 mm/s

Vibration after balancing: 0.7 and 3.1 mm/s

Balancing was performed using the Balanset-1A device.

Need to balance a rotor yourself? See the Balanset-1A and the price list.

Balanset-1A Price list

All blog posts