Compressor fan turbine balancing at 1386 rpm
We are sharing a recent practical case. The goal was to eliminate excessive vibration in the fan turbine of a compressor (rotation speed: 1386 rpm).
Initial data: before the work, vibration levels reached critical values of 23.3 and 24.3 mm/s.
The process: a trial weight of only 5 grams was used for the diagnosis. The procedure was carried out in two stages:
Elimination of the main imbalance in one plane.
Finishing balancing in two planes for maximum precision.
Result: residual vibration dropped to 0.6 and 1.0 mm/s. The proof of the quality of the work is the coin test: the coin stays perfectly still, upright, on the running equipment. The customer was satisfied and the compressor returned to normal operation.